Navvion Epsilon
Liquid-cooling 20-ft container, 2612 kWh / 1250 kW.
- 2612 kWh
- Rated Capacity
- 1250 kW
- Rated Power
- Liquid-Cooled
- Thermal System

Overview
Built for industrial reliability.
A standard 20-ft container integrating battery packs, PCS, liquid-cooled thermal management, and fire suppression into one smart energy storage solution. Customisable capacity up to 1560 kW / 3134 kWh for commercial and industrial use.
Integrated AC and DC blocks
Battery packs, PCS, liquid-cooled thermal management, and fire suppression share one 20-ft container — raising energy density and system efficiency while cutting site work.
Deeper usable discharge
Cluster-level management resolves SOC imbalance between the ten battery clusters, unlocking a greater depth of discharge from the same installed capacity.
Customisable to 3134 kWh
The platform configures from the standard 2612 kWh / 1250 kW up to 1560 kW / 3134 kWh, matching container capacity to each project's load profile.
Three-layer safety response
Aerosol suppression, water-based suppression, and controlled ventilation act in sequence to contain thermal events inside the container envelope.
Applications
Where this product works.
Every deployment links to Navvion APM.
Site onboarding, performance monitoring, alerts, warranty data, remote diagnostics, and service dispatch — from one console.
Trained installers. Local parts.
Deployment through certified partners, documented commissioning, APM onboarding, spare parts planning, and warranty/RMA workflows.
Specifications
Every parameter that matters.
| Rated Power | 1250 kW |
| Rated Voltage (AC) | 230 / 400 V, 3P+N+PE |
| Rated Frequency | 50 / 60 Hz |
| Power Factor | 0.8 lead ~ 0.8 lag |
| Rated Capacity | 2612 kWh |
| DC Max Current | 172 A × 10 |
| Battery Type | LFP 3.2 V / 314 Ah |
| Rated Voltage (DC) | 832 V |
| Voltage Range | 728 ~ 949 V |
| System Configuration | 10P260S |
| Dimensions (W×D×H) | 6058 × 2438 × 2896 mm |
| Weight | ~35 t |
| Cooling Method | Liquid Cooling (DC Side) |
| IP Rating | IP54 |
| Operating Temperature | -20 °C ~ +40 °C |
| Relative Humidity | 5% ~ 95% |
| Altitude | ≤ 2000 m |
| Noise Emission | ≤ 75 dB |
| Fire Suppression | Aerosol |
| Standards | IEC/EN 62477-1 · IEC/EN 61000-6-2 · IEC/EN 61000-6-4 · IEC 62619 · G99 · G100 · AS4777.2 · EN 50549-1 · VDE-AR-N 4110 · UN38.3 |
Certifications
Aligned with international standards.
Navvion maintains a per-market certification roadmap covering documentation, testing, and local review.
Gallery
Around the system.

FAQ
Common questions.
Can the capacity be customised?
Yes. The standard configuration is 2612 kWh / 1250 kW, and the same 20-ft platform can be configured up to 1560 kW / 3134 kWh for larger C&I deployments.
What is the grid connection?
Rated output is 1250 kW at 230/400 V, 3P+N+PE, 50/60 Hz, with power factor adjustable from 0.8 leading to 0.8 lagging.
What operating environment does it support?
The container operates from -20 °C to +40 °C, 5–95% relative humidity, altitudes up to 2000 m, with an IP54 enclosure and noise at or below 75 dB.
How does liquid cooling help in daily cycling?
The DC-side liquid loop keeps cell temperatures uniform under sustained charge/discharge, which slows degradation and protects capacity over the project's life.
How is the system monitored?
The container connects to Navvion APM for site and fleet monitoring, alarm management, and remote diagnostics across all ten battery clusters.